1-321-802-5889

NSN 5925-00-865-9618

Overload Switch

About this product

0.250 inches mounting slot width, plastic case material, 1 poles, arc quenching method: magnetic blowout.

Manufacturer part number NEF214020 for national stock number 5925008659618.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-00-865-9618.

  • MPN or Model

    NEF214020

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    0.5 lb
  • Mounting Slot Width
    0.250 inches
  • Body Length
    6.219 inches
  • Body Width
    1.375 inches
  • Body Height
    3.406 inches
  • Case Material
    Plastic
  • Center To Center Distance Between Terminals Parallel To Length
    5.125 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
    5.219 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
    1.125 inches
  • Boss Height
    0.203 inches
  • Pole Quantity
    1
  • Arc Quenching Method
    Magnetic blowout
  • Mounting Facility Type And Quantity
    4 slot
  • Storage Type
    General purpose warehouse
  • Maximum Continuous Load Current Rating Per Pole
    20.0 amperes ac single location and 20.0 amperes dc single location
  • Operating Voltage Type And Rating Per Pole In Volts
    277.0 ac single location and 125.0 dc single location
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    14000.0 ac single location and 10000.0 dc single location
  • Circuit Protection Type
    Overcurrent single location
  • Trip Release Method
    Thermal-magnetic single location
  • Trip Release Characteristic
    Instantaneous single location and time delay single location
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    140.0 single location
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole one
  • Trip Delay Time In Seconds Per Rated Continuous Current
    24.000 at 200 pct single location and 65.000 at 200 pct single location
  • Inclosure Protection Type For Which Designed
    General purpose
  • Trip Release Ambient Tempurature Rating
    40.0 degrees celsius single location
  • Frequency In Hertz
    60.0 single location
  • Terminal Type And Quantity
    2 compression
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-00-865-9618 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925008659618

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
NEF214020 Challenger Electrical Equipment Corp
NEF213020 Challenger Electrical Equipment Corp
NEF212020 Challenger Electrical Equipment Corp
NEF212020 Challenger Acquisition Corp
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.