NSN 5925-01-069-0274
Overload Switch
Single pole type body style, metal case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number SP-CI-004-002 for national stock number 5925010690274.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-069-0274.
-
MPN or Model
SP-CI-004-002
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Body Style
Single pole type -
Bushing Length
0.190 inches -
Body Length
0.750 inches -
Body Width
0.562 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.703 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.812 inches -
Pole Quantity
1 -
Arc Quenching Method
Air -
Mounting Facility Type And Quantity
1 threaded bushing -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes ac single location and 500.0 milliamperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 28.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
145.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push-pull -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.469 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct single location and 20.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Corrosion resistant and explosion proof and moisture resistant -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location -
Frequency In Hertz
400.0 single location -
Thread Series Designator
Uns -
Terminal Type And Quantity
2 screw
More from these suppliers
- 5930-00-263-2925 MPN 20640L29Thermostatic Switch
- 5930-00-927-2891 MPN 20410LL190-24995-1Thermostatic Switch
- 5930-01-004-5249 MPN M1-185-165-132Thermostatic Switch
- 5930-01-089-3563 MPN M221L-202-0404-21Thermostatic Switch
- 5930-01-300-7500 MPN 26260-1Thermostatic Switch
- 5930-01-604-1549 MPN M222F135030422Thermostatic Switch
- 5925-00-182-7452 MPN 4MC1-7-50Circuit Breaker
- 5925-00-227-0395 MPN PDLM-35Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-069-0274 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
SP-CI-004-002 | Gould Inc |
7274-11-1/2 12507-57-15 | Sensata Technologies, Inc |
7274-11-1-2-SR12507-57-15 | Sensata Technologies, Inc |
Stock Check