NSN 5925-01-261-7872
Overload Switch
Amps marked on item is for training only.
Manufacturer part number 44-200-P10-S1-043.800-25 for national stock number 5925012617872.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-261-7872.
-
MPN or Model
44-200-P10-S1-043.800-25
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Bushing Length
6.5 millimeters -
Body Length
19.8 millimeters -
Body Width
15.8 millimeters -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
12.7 millimeters -
Switch Contact Arrangement
Double pole, double throw -
Mounting Surface To Terminal End Distance
43.5 millimeters -
Pole Quantity
1 -
Mounting Facility Type And Quantity
1 threaded bushing -
Maximum Continuous Load Current Rating Per Pole
100.0 milliamperes ac single location and 100.0 milliamperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location and 28.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location and 1000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push-pull -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip single location -
Thread Size
12.0 millimeters -
Thread Pitch In Millimeters
1.25 -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 at 200 pct single location and 60.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
General purpose -
Trip Release Ambient Tempurature Rating
150.0 degrees fahrenheit single location -
Switch Terminal Type
Quick disconnect, male -
Criticality Code Justification
Feat -
Switch Current Rating And Type In Amps
1.0 ac and 5.0 dc -
Switch Voltage Rating And Type In Volts
220.0 ac and 28.0 dc -
Frequency In Hertz
400.0 single location -
Thread Series Designator
Iso m -
Terminal Type And Quantity
2 quick disconnect, male
More from these suppliers
- 4920-01-471-2702 MPN 305970-1Electrical-electronic Equipment Test Station
- 5985-01-410-7776 MPN 232316-1Antenna Support Group
- 5306-00-316-6477 MPN 342-106196-7Internal Wrenching Bolt
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-261-7872 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
44-200-P10-S1-043.800-25 | Oakland Industries Ltd |
216556-10 | Cubic Defense Applications, Inc. |