NSN 5925-01-564-0125
Overload Switch
Multipole-multiple actuator type body style, 2 poles, 2.5 amperes ac all locations maximum continuous load current rating per pole, circuit protection type: overcurrent all locations.
Manufacturer part number IAGN66-1-61-2.5 for national stock number 5925015640125.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-564-0125.
-
MPN or Model
IAGN66-1-61-2.5
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Bushing Length
0.240 inches -
Body Length
2.000 inches -
Body Width
1.515 inches -
Center To Center Distance Between Terminals Parallel To Length
1.530 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches -
End Application
60173-80 (12763), dias cabinet(cg, ddg, lcs1) -
Mounting Surface To Terminal End Distance
2.075 inches -
Pole Quantity
2 -
Maximum Continuous Load Current Rating Per Pole
2.5 amperes ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Part Name Assigned By Controlling Agency
(inavy)ckt bkr, 2.5amp -
Terminal Type And Quantity
4 screw
More from these suppliers
- 5945-00-220-3562 MPN 62083-019Electromagnetic Relay
- 5930-01-558-8285 MPN 66506-805Linear Movement Switch Assy
- 6110-01-595-6375 MPN P/L 66736-000 FN: 54Electrical System Protection Panel
- 6110-01-595-6958 MPN P/L 66736-000 FN: 22Electrical System Protection Panel
- 5925-00-409-3604 MPN APL1-1-6-2-103Circuit Breaker
- 5925-00-937-9572 MPN AP12-1388-2Circuit Breaker
- 5925-01-004-9293 MPN 203-2-1-61-252-4-1-1Circuit Breaker
- 5925-01-057-8862 MPN AP112-2066-4Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-564-0125 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
IAGN66-1-61-2.5 | Sensata Technologies Maryland, Inc |
14046-033 | Dynalec Corporation |
Stock Check
![](/public/images/partscage_shelf3.png)