1-321-802-5889

NSN 5985-00-162-5936

Load Waveguide

About this product

0.7 gallons per minute cooling system coolant flow rate, +8.500/+11.000 gigahertz frequency range rating, 1.20 voltage standing wave ratio, power rating: 200.000 watts average.

Manufacturer part number 452336 for national stock number 5985001625936.

Datasheet

  • Product description

    Electrical Dummy Load NSN 5985-00-162-5936.

  • MPN or Model

    452336

  • Schedule B
    9030.33.0080 (Other instruments and apparatus for measuring or checking power, without a recording device, nesoi)
  • NMF (National Motor Freight)
    062960 - Reostats/parts NOI
  • Unit Weight (Est.)
    40 lb
  • Cooling System Coolant Flow Rate
    0.7 gallons per minute
  • Overall Length
    3.190 inches
  • Overall Height
    1.620 inches
  • Overall Width
    Between 1.610 inches and 1.640 inches
  • Body Width
    Between 1.610 inches and 1.640 inches
  • Body Height
    1.620 inches
  • Frequency Range Rating
    +8.500/+11.000 gigahertz
  • Voltage Standing Wave Ratio
    1.20
  • Power Rating
    200.000 watts average
  • Termination Type
    Waveguide flange
  • Waveguide Flange Designation
    Ug-135/u
  • Operating Position
    All positions
  • Internal Operating Pressure
    45.0 pounds per square inch gage
  • Coolant Chamber Pressure
    15.0 pounds per square inch gage
  • Input Coolant Temp
    18.0 degrees celsius
  • Cooling Method
    Forced liquid
  • Style Designator
    Waveguide mounted
More from these suppliers
Electrical Dummy Load

A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also load bank, electrical.

Mechanic Bill explains Load Waveguide

Pricing and Availability

Get a quote for 5985-00-162-5936 electrical dummy load
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5985001625936

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
452336 Continental Microwave And Tool Co.,
928088-5 Raytheon Company
WL-A71 Microlab/fxr
86778 Herley Industries, Inc.
928088-5 3dbm Co Inc
928088-5 Continental Microwave And Tool Co.,
928088-5 Advanced Technical Materials, Inc.
13183 Connecticut Microwave Corp
452336 Litton Systems Inc
13183 Miller, Harry Corp, The
13183 Mercury Commercial Electronics, Inc.
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.