NSN 5985-01-323-1729
Load Waveguide
5.0 gallons per minute cooling system coolant flow rate, +2.900/+3.100 gigahertz frequency range rating, 1.10 and 1.30 voltage standing wave ratio, power rating: 3.200 megawatts peak and 25.000 kilowatts average.
Manufacturer part number 168363-1 for national stock number 5985013231729.
Datasheet
-
Product description
Electrical Dummy Load NSN 5985-01-323-1729.
-
MPN or Model
168363-1
-
Schedule B
9030.33.0080 (Other instruments and apparatus for measuring or checking power, without a recording device, nesoi) -
NMF (National Motor Freight)
062960 - Reostats/parts NOI -
Unit Weight (Est.)
15 lb -
Cooling System Coolant Flow Rate
5.0 gallons per minute -
Overall Length
13.000 inches -
Overall Width
5.750 inches -
Body Diameter
4.000 inches -
Frequency Range Rating
+2.900/+3.100 gigahertz -
End Application
Ot-141/sps-48e, transmitter group -
Voltage Standing Wave Ratio
1.10 and 1.30 -
Power Rating
3.200 megawatts peak and 25.000 kilowatts average -
Voltage Standing Wave Ratio Frequency Range
+2.900/+3.100 gigahertz and +2.400/+3.200 gigahertz -
Termination Type
Waveguide flange -
Operating Position
All positions -
Coolant Chamber Pressure
150.0 pounds per square inch gage -
Input Coolant Temp
55.0 degrees celsius -
Cooling Method
Forced liquid -
Style Designator
Waveguide mounted
More from these suppliers
- 5985-00-111-0524 MPN 127897-1Waveguide Assembly
- 5930-00-451-7265 MPN 5560432-11Rotary Switch
- 5950-00-578-8141 MPN 72183-3Radio Frequency Transformer
- 5950-00-647-7407 MPN 23587Power Transformer
- 5935-00-993-8939 MPN G350022-12Electrical Receptacle Connector Body
- 5950-01-172-8558 MPN 188306-1Electrical Coil
- 5950-01-186-0201 MPN 188398-1Radio Frequency Coil
- 5975-01-573-7897 MPN 299801-1Electrical-electronic Equipment Panel
A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also load bank, electrical.
Pricing and Availability
Get a quote for 5985-01-323-1729 electrical dummy loadManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
168363-1 | Harris Corporation |