NSN 5985-01-518-2626
Load Waveguide
Fac power requirements 230 vac, single phase 27.5 amp; 208-230/460 vac, three phase 9.6/4.8 amp; finish beige splatter; fan 1.5 hp centrifugal; pump 1.5 hp centrifugal; vswr 60 hz to 800mhz 1.1:1 max.
Manufacturer part number 5850 for national stock number 5985015182626.
Datasheet
-
Product description
Electrical Dummy Load NSN 5985-01-518-2626.
-
MPN or Model
5850
-
Schedule B
9030.33.0080 (Other instruments and apparatus for measuring or checking power, without a recording device, nesoi) -
Impedance Rating In Ohms
50.0 -
Power Rating
50.000 kilowatts average -
Termination Type
Connector -
Cooling Method
Forced liquid -
Functional Description
Model 5850 rf heat exchanger is a model 9750 50 ohm resistor assembly cooled by a vented, closed-loop water system, utilizing a centrifugal pump, water-to-air heat exchanger, capacity of coolant is approx 11 us gallons, and 1 centrifugal blower; blower assembly is a 1.5 hp belt-driven centrifugal blower, blower moves air into a closed plenum, through the heat exchanger coil to the rear of unit -
Supplementary Features
Location should be dry, free of excessive dust and ambient temp p5.0 to 35 degrees c with water only and m20.0 to 30.0 degrees c with porm 35 pct ethylene glycol mixture; room well ventilated; rf dissipation of unit is 50, 000 watts equals 170.650 btu/hr usually ducted out of building; not necessary to mount which is designed to be a free-standing device resting on 4 heavy duty casters; brakes are installed on swivel casters; 4 terminal, captive-screw terminal strip
A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also load bank, electrical.
Pricing and Availability
Get a quote for 5985-01-518-2626 electrical dummy loadManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
5850 | Altronic Research, Incorporated |