NSN 5985-01-569-7081
Load Waveguide
Temp range: -35 to +125 deg celcius; connector finish: inner layer-silver plated, outer layer-cu-sn-zn plate; housing finish: black oxidization.
Manufacturer part number T-10-NF for national stock number 5985015697081.
Datasheet
-
Product description
Electrical Dummy Load NSN 5985-01-569-7081.
-
MPN or Model
T-10-NF
-
Schedule B
9030.33.0080 (Other instruments and apparatus for measuring or checking power, without a recording device, nesoi) -
NMF (National Motor Freight)
062960 - Reostats/parts NOI -
Overall Length
54.0 millimeters -
Impedance Rating In Ohms
50.0 -
Overall Diameter
35.0 millimeters -
Frequency Range Rating
+0.000/+3.000 gigahertz -
End Application
Wsd: nuclear power plants -
Voltage Standing Wave Ratio
1.15 -
Coaxial Connector Series Designation
N -
Connector End Design
Female -
Power Rating
10.000 watts average and 1.500 kilowatts peak -
Termination Type
Connection coaxial -
Operating Position
All positions -
Cooling Method
Self-cooled -
Part Name Assigned By Controlling Agency
Medium power coaxial loads/terminations -
Style Designator
Coaxial mounted
More from these suppliers
- 4820-00-090-9812 MPN 5901-3214967REVBPC9AT09FCheck Valve
- 5950-00-211-1464 MPN 2919948Current Transformer
- 4820-00-288-7842 MPN 212-58-012PCV5496Safety Relief Valve
- 5945-00-345-7467 MPN 5265696Electromagnetic Relay
- 5975-00-381-7186 MPN 177040PC104Cable Marker Sleeve
- 4820-00-438-2699 MPN 803-5001003-M5XX-03A,04Ball Valve Parts Kit
- 4820-00-446-3560 MPN AK29S49-24ALT3PC11Safety Relief Valve
- 5950-00-484-2515 MPN 2686377REVBReactor-transformer
A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also load bank, electrical.
Pricing and Availability
Get a quote for 5985-01-569-7081 electrical dummy loadManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
T-10-NF | Andrew Llc |
433-8216658-009 | Naval Sea Systems Command |
H671-2002-009 | Electric Boat Corporation |
245574 | Andrew Llc |