1-321-802-5889

NSN 5925-00-005-3114

Overload Switch

About this product

Multipole-single actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 3.

Manufacturer part number MCP331000R for national stock number 5925000053114.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-00-005-3114.

  • MPN or Model

    MCP331000R

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    5.3 lb
  • Body Style
    Multipole-single actuator type
  • Body Length
    6.000 inches
  • Body Width
    4.125 inches
  • Body Height
    3.375 inches
  • Case Material
    Plastic
  • Center To Center Distance Between Terminals Parallel To Length
    5.062 inches
  • Center To Center Distance Between Terminals Parallel To Width
    1.375 inches
  • Unthreaded Mounting Hole Diameter
    0.187 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
    4.500 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
    1.375 inches
  • Fragility Factor
    Moderately rugged
  • Boss Height
    0.125 inches
  • Pole Quantity
    3
  • Mounting Facility Type And Quantity
    4 unthreaded hole
  • Storage Type
    General purpose warehouse
  • Maximum Continuous Load Current Rating Per Pole
    100.0 amperes ac all locations
  • Operating Voltage Type And Rating Per Pole In Volts
    600.0 ac all locations
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    14000.0 ac all locations
  • Circuit Protection Type
    Overcurrent all locations
  • Trip Release Method
    Magnetic all locations
  • Trip Release Characteristic
    Time delay all locations
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    130.0 all locations
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole two
  • Internal Trip Release Configuration
    Series trip all locations
  • Trip Delay Time In Seconds Per Rated Continuous Current
    200.000 at 200 pct all locations
  • Inclosure Protection Type For Which Designed
    Fungus resistant and moisture resistant
  • Frequency In Hertz
    60.0 all locations
  • Terminal Type And Quantity
    6 compression
More from these suppliers
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-00-005-3114 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925000053114

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
MCP331000R Eaton Corporation
C528-11 Hamilton Sundstrand Corporation
23739 Erie Strayer Company
4994D97G27 Eaton Corporation
MCP331000 Eaton Corporation
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.