1-321-802-5889

NSN 5925-00-009-5521

Overload Switch

About this product

Single pole type body style, metal case material, single pole, double throw switch contact arrangement, pole quantity: 1.

Manufacturer part number 2638051-151 for national stock number 5925000095521.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-00-009-5521.

  • MPN or Model

    2638051-151

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Body Style
    Single pole type
  • Bushing Length
    Between 0.280 inches and 0.380 inches
  • Body Length
    1.562 inches
  • Body Width
    0.625 inches
  • Case Material
    Metal
  • Center To Center Distance Between Terminals Parallel To Length
    0.906 inches
  • Switch Contact Arrangement
    Single pole, double throw
  • Mounting Surface To Terminal End Distance
    1.700 inches
  • Pole Quantity
    1
  • Mounting Facility Type And Quantity
    1 threaded bushing w/panel seal
  • Thready Qty Per Inch (tpi)
    32
  • Maximum Continuous Load Current Rating Per Pole
    5.0 amperes ac single location
  • Operating Voltage Type And Rating Per Pole In Volts
    240.0 ac single location
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    300.0 ac single location
  • Circuit Protection Type
    Overcurrent single location
  • Trip Release Method
    Magnetic single location
  • Trip Release Characteristic
    Time delay single location
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    125.0 single location
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    2 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole one
  • Auxiliary Switch Function And Quantity
    1 alarm
  • Internal Trip Release Configuration
    Series trip single location
  • Thread Size
    0.375 inches
  • Switch Location And Position Designation
    Internal at pole one
  • Trip Delay Time In Seconds Per Rated Continuous Current
    0.500 at 200 pct single location and 9.000 at 200 pct single location
  • Inclosure Protection Type For Which Designed
    Hermetically sealed
  • Switch Terminal Type
    Wire hook
  • Switch Current Rating And Type In Amps
    0.5 ac and 0.5 dc
  • Switch Voltage Rating And Type In Volts
    120.0 ac and 50.0 dc
  • Frequency In Hertz
    60.0 single location
  • Thread Series Designator
    Unef
  • Terminal Type And Quantity
    2 wire hook
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-00-009-5521 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925000095521

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
2638051-151 Navair And Navsea Managed
T505-004-351 Lockheed Martin Librascope
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.