NSN 5925-00-011-7011
Overload Switch
Multipole-multiple actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number A15912-006 for national stock number 5925000117011.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-011-7011.
-
MPN or Model
A15912-006
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
1.3 lb -
Body Style
Multipole-multiple actuator type -
Body Length
2.530 inches -
Body Width
3.060 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.940 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.750 inches and 0.770 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.050 inches and 2.070 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.750 inches and 0.770 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.150 inches -
Mounting Surface To Terminal End Distance
2.522 inches -
Pole Quantity
4 -
Mounting Facility Type And Quantity
8 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay first locationtime delay second locationtime delay third locationinstantaneous fourth location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
4 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, three, and four linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip first locationseries trip second locationseries trip third locationrelay trip fourth location -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole three -
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 at 200 pct first location and 5.000 at 200 pct first location0.600 at 200 pct second location and 5.000 at 200 pct second location0.600 at 200 pct third location and 5.000 at 200 pct third location -
Inclosure Protection Type For Which Designed
Vibration resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc -
Switch Voltage Rating And Type In Volts
50.0 dc -
Frequency In Hertz
400.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
10 threaded stud -
Specification Data
12436-a15912 government specification
More from these suppliers
- 5905-00-578-4685 MPN 36568Noninductive Wire Wound Fixed Resistor
- 5950-00-645-7229 MPN 647271-000Radio Frequency Coil
- 5950-00-778-9049 MPN 666096-350Radio Frequency Coil
- 5935-00-938-1078 MPN 696280-505Electrical Plug Connector
- 4920-01-246-8867 MPN 3204120-001Test Program Set
- 5935-01-251-4074 MPN 2119011-035Electrical Connector Assembly
- 4920-01-336-8059 MPN 2231850-004Aircraft Components Test Set Subassembly
- 5935-01-397-0193 MPN 6012005-011Electrical Connector Backshell
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-011-7011 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
A15912-006 | Bae Systems Information And |
73-115-6MG6-30-250VAC400-16 | Eaton Corp |