NSN 5925-00-011-7011

Overload Switch

About this product

Multipole-multiple actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.

Manufacturer part number A15912-006 for national stock number 5925000117011.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-00-011-7011.

  • MPN or Model

    A15912-006

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    1.3 lb
  • Body Style
    Multipole-multiple actuator type
  • Body Length
    2.530 inches
  • Body Width
    3.060 inches
  • Case Material
    Plastic
  • Center To Center Distance Between Terminals Parallel To Length
    1.940 inches
  • Center To Center Distance Between Terminals Parallel To Width
    Between 0.750 inches and 0.770 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
    Between 2.050 inches and 2.070 inches
  • Switch Contact Arrangement
    Single pole, double throw
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
    Between 0.750 inches and 0.770 inches
  • Fragility Factor
    Moderately rugged
  • Boss Height
    0.150 inches
  • Mounting Surface To Terminal End Distance
    2.522 inches
  • Pole Quantity
    4
  • Mounting Facility Type And Quantity
    8 threaded hole
  • Storage Type
    General purpose warehouse
  • Special Handling Feature
    Magnetic
  • Thready Qty Per Inch (tpi)
    32
  • Maximum Continuous Load Current Rating Per Pole
    30.0 amperes ac all locations
  • Operating Voltage Type And Rating Per Pole In Volts
    250.0 ac all locations
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    1500.0 ac all locations
  • Circuit Protection Type
    Overcurrent all locations
  • Trip Release Method
    Magnetic-hydraulic all locations
  • Trip Release Characteristic
    Time delay first locationtime delay second locationtime delay third locationinstantaneous fourth location
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    150.0 all locations
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    4 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At each pole
  • External Actuator Linkage Arrangement
    One, two, three, and four linked
  • Auxiliary Switch Function And Quantity
    1 alarm
  • Internal Trip Release Configuration
    Series trip first locationseries trip second locationseries trip third locationrelay trip fourth location
  • Thread Size
    0.138 inches
  • Switch Location And Position Designation
    Internal at pole three
  • Trip Delay Time In Seconds Per Rated Continuous Current
    0.600 at 200 pct first location and 5.000 at 200 pct first location0.600 at 200 pct second location and 5.000 at 200 pct second location0.600 at 200 pct third location and 5.000 at 200 pct third location
  • Inclosure Protection Type For Which Designed
    Vibration resistant
  • Switch Terminal Type
    Tab, solder lug
  • Switch Current Rating And Type In Amps
    5.0 ac and 1.0 dc
  • Switch Voltage Rating And Type In Volts
    50.0 dc
  • Frequency In Hertz
    400.0 all locations
  • Thread Series Designator
    Unc
  • Terminal Type And Quantity
    10 threaded stud
  • Specification Data
    12436-a15912 government specification
More from these suppliers
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-00-011-7011 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925000117011

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
A15912-006 Bae Systems Information And
73-115-6MG6-30-250VAC400-16 Eaton Corp
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.