NSN 5925-00-024-0863
Overload Switch
Plastic case material, moderately rugged fragility factor, 3 poles, arc quenching method: magnetic blowout.
Manufacturer part number 659001CB2 for national stock number 5925000240863.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-024-0863.
-
MPN or Model
659001CB2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.8 lb -
Body Length
Between 2.490 inches and 2.510 inches -
Body Width
Between 2.240 inches and 2.260 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.928 inches and 1.948 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.740 inches and 0.760 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.052 inches and 2.072 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.740 inches and 0.760 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.130 inches and 0.150 inches -
Mounting Surface To Terminal End Distance
Between 2.461 inches and 2.481 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Unpackaged Unit Weight
14.000 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5925-00-300-3216 MPN AM1-A3-A-7-2Circuit Breaker
- 5925-00-542-8780 MPN AM13RSK0 75-8Circuit Breaker
- 5925-01-024-9568 MPN AM12MG6-3-120VAC60C4Circuit Breaker
- 5925-01-034-8043 MPN JA1-A3-4-2Circuit Breaker
- 5925-01-053-1449 MPN CD1B3-25-3Circuit Breaker
- 5925-01-111-9949 MPN AM4-A6A3A3A3-A-30-250-3Circuit Breaker
- 5925-01-257-4310 MPN GJ2-Z35-1Circuit Breaker
- 5925-01-338-4997 MPN AM12MG3-3-28DC4Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-024-0863 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
659001CB2 | Thermo Jarrell Ash Corp |
651321 | Thermo Jarrell Ash Corp |
72-289-1MG6 | Eaton Corp |
Stock Check
![](/public/images/partscage_shelf3.png)