NSN 5925-00-027-1579
Overload Switch
Single pole type body style, plastic case material, 1 poles, thready qty per inch (tpi): 32.
Manufacturer part number 271-1290P24 for national stock number 5925000271579.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-027-1579.
-
MPN or Model
271-1290P24
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Body Style
Single pole type -
Body Length
2.500 inches -
Body Width
0.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches -
Boss Height
0.125 inches -
Mounting Surface To Terminal End Distance
2.359 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
2 threaded hole -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location -
Ultimate Trip Time Per Pole In Seconds
7.000 single location and 29.000 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 at 200 pct single location and 9.500 at 200 pct single location -
Inclosure Protection Type For Which Designed
Fungus resistant and general purpose and weatherproof -
Frequency In Hertz
60.0 single location -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5940-00-045-8514 MPN 50362-5211Terminal Board
- 5905-00-069-3468 MPN 29-544Nonprecision Wire Wound Variable Resistor
- 5950-00-162-4391 MPN 375-2241G14Radio Frequency Coil
- 5935-00-169-2430 MPN 267MT272P001Electrical Receptacle Connector
- 5950-00-198-8524 MPN DL74-663Power Transformer
- 5945-00-237-1175 MPN U746-891AH1Electromagnetic Relay
- 5950-00-250-1132 MPN 1000A115Radio Frequency Coil
- 5930-00-263-7831 MPN L28-5135Rotary Switch
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-027-1579 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
271-1290P24 | Raytheon Company |
271-1290P24 | Raytheon Company |
70-613-15AMP60C115VC4 | Eaton Corp |
271-1290P24 | Raytheon Company |
Stock Check