NSN 5925-00-042-7805
Overload Switch
Single pole type body style, metal case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number L505001064 for national stock number 5925000427805.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-042-7805.
-
MPN or Model
L505001064
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.2 lb -
Body Style
Single pole type -
Bushing Length
0.380 inches -
Body Length
1.622 inches -
Body Width
0.625 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.906 inches -
Switch Contact Arrangement
Single pole, double throw -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.656 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Instantaneous single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location -
Ultimate Trip Time Per Pole In Seconds
0.005 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 control -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.375 inches -
Switch Location And Position Designation
Internal at pole one -
Inclosure Protection Type For Which Designed
Hermetically sealed -
Switch Terminal Type
Wire hook -
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc -
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc -
Frequency In Hertz
60.0 single location -
Thread Series Designator
Unef -
Terminal Type And Quantity
2 wire hook
More from these suppliers
- 4820-00-003-8640 MPN 2419740Check Valve
- 5905-00-012-5029 MPN 2467393PC1Nonprecision Wire Wound Variable Resistor
- 5930-00-026-8384 MPN 658842Thermostatic Switch
- 5950-00-052-1017 MPN 2558884Radio Frequency Transformer
- 5940-00-139-5437 MPN 2423855-1Terminal Board
- 5905-00-158-4984 MPN 664268-11Noninductive Wire Wound Fixed Resistor
- 5905-00-158-7583 MPN 589012-1Precision Wire Wound Variable Resistor
- 5950-00-169-8830 MPN 1589535Power Transformer
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-042-7805 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
L505001064 | Lockheed Martin Librascope |
2282221-24 | Navair And Navsea Managed |