NSN 5925-00-062-6921
Overload Switch
Multipole-single actuator type body style, plastic case material, 2 poles, maximum continuous load current rating per pole: 20.0 amperes ac all locations and 20.0 amperes dc all locations.
Manufacturer part number NEF425020-50DEGC for national stock number 5925000626921.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-062-6921.
-
MPN or Model
NEF425020-50DEGC
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Body Style
Multipole-single actuator type -
Overall Length
6.219 inches -
Overall Height
3.406 inches -
Overall Width
2.750 inches -
Body Length
6.062 inches -
Body Width
2.750 inches -
Body Height
3.406 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
5.219 inches -
Center To Center Distance Between Terminals Parallel To Width
1.375 inches -
Unthreaded Mounting Hole Diameter
0.225 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
5.125 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches -
Boss Height
0.188 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
4 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations and 20.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac all locations and 250.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac all locations and 10000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Instantaneous all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
Between pole one and two -
Inclosure Protection Type For Which Designed
Fungus resistant -
Trip Release Ambient Tempurature Rating
50.0 degrees celsius all locations -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
4 compression
More from these suppliers
- 5945-01-283-9049 MPN DA-8509-093-A001 ITEM 68Solid State Relay
- 5950-01-307-6958 MPN 240A-518-7Electrical Coil
- 5925-00-100-5152 MPN XF631020-50DEGCCircuit Breaker
- 5925-01-025-0320 MPN NEF433050Circuit Breaker
- 6110-01-283-6958 MPN DA86-02-105C-014Motor Starter
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-062-6921 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
NEF425020-50DEGC | Challenger Electrical Equipment Corp |
NEF421020-50DEGC | Challenger Electrical Equipment Corp |
NEF423020-50DEGC | Challenger Electrical Equipment Corp |