NSN 5925-00-066-6891
Overload Switch
Mtg holes on 4.848 in. By 1.375 in. Mtg centers.
Manufacturer part number 1532383A for national stock number 5925000666891.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-066-6891.
-
MPN or Model
1532383A
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Overall Length
6.000 inches -
Overall Height
2.750 inches -
Overall Width
1.970 inches -
Case Material
Plastic -
Pole Quantity
2 -
Arc Quenching Method
Deion -
Mounting Facility Type And Quantity
4 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations and 20.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations and 250.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
7500.0 ac all locations and 7500.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
120.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Actuator Function
Trip w/separate reset -
Thread Size
0.188 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
100.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Dustproof -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
4 screw
More from these suppliers
- 5945-00-024-1098 MPN 1JH2415PC1FRelay
- 5905-00-100-6302 MPN 900C350-12Inductive Wire Wound Fixed Resistor
- 5905-00-114-4945 MPN 31J44ITEM61Adjustable Resistor
- 4820-00-147-3786 MPN D15-664MPC823Valve Cap
- 5950-00-232-4758 MPN T7606138Electrical Coil
- 5905-00-332-9324 MPN 37J345ITEM24Resistor
- 5905-00-333-1125 MPN 36J82ITEM26Inductive Wire Wound Fixed Resistor
- 5975-00-519-5748 MPN 96122Electrical Wall Plate
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-066-6891 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
1532383A | Eaton Corporation |