NSN 5925-00-109-1792
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number PSM10 for national stock number 5925001091792.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-109-1792.
-
MPN or Model
PSM10
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Overall Length
2.187 inches -
Body Width
0.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
0.780 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.812 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.296 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
1 threaded bushing -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac single location and 10.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
30.0 ac single location and 30.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
200.0 ac single location and 200.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
120.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push button -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
21.000 at 200 pct single location and 6.600 at 300 pct single location -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location -
Frequency In Hertz
60.0 single location -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 screw
More from these suppliers
- 5940-00-636-6363 MPN A51648Conductor Splice
- 1560-00-474-8919 MPN 60761-00Top Deck Fron Cover
- 1560-00-773-6234 MPN 750035Fairing
- 5306-01-494-9411 MPN 400003Machine Bolt
- 5305-00-151-2288 MPN 6700-636385-416Machine Screw
- 6105-00-635-2850 MPN 8160020AAG1Motor Armature
- 5930-00-476-8194 MPN C4391N14-28Thermostatic Switch
- 5930-00-843-6030 MPN KX5-2-25Sensitive Switch
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-109-1792 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
PSM10 | Sensata Technologies, Inc |
43A8304-10 | Department Of The Air Force |
454649 | Piper Aircraft Inc. |
49940 | Numax Electronics Inc |
MCM2810 | General Electric Co |
Stock Check
- NS: 87
- NE: 255