NSN 5925-00-119-8654
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number X0411-20-120-9 for national stock number 5925001198654.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-119-8654.
-
MPN or Model
X0411-20-120-9
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.5 lb -
Body Style
Single pole type -
Body Length
Between 4.740 inches and 4.760 inches -
Body Width
Between 1.020 inches and 1.040 inches -
Body Height
Between 2.820 inches and 2.840 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 4.370 inches and 4.390 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.740 inches and 2.760 inches -
Fragility Factor
Moderately rugged -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
39.000 at 200 pct single location and 105.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
General purpose -
Frequency In Hertz
60.0 single location -
Unpackaged Unit Weight
0.688 pounds -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 bus bar
More from these suppliers
- 5945-00-146-8671 MPN BN1-522XBX24VDC1Electromagnetic Relay
- 5930-01-134-4840 MPN AM2-A0-50Toggle Switch
- 5925-00-054-0100 MPN AM17MG3-15-120-208AC400-55Circuit Breaker
- 5925-00-081-8720 MPN SM333-10-250VAC400C2Circuit Breaker
- 5925-00-429-1628 MPN AM33HKMG3-2-230VAC4Circuit Breaker
- 5925-00-723-4912 MPN 3XAM17-15-115VAC400C55Circuit Breaker
- 5925-00-879-0971 MPN AM17-50Circuit Breaker
- 5925-00-925-2164 MPN SM333-L1.6-C0.25-R2.0-240V400C1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-119-8654 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
X0411-20-120-9 | Eaton Corp |
X0411-20-240VAC60C9 | Eaton Corp |