NSN 5925-00-132-3607
Overload Switch
Metal case material, 1 poles, 32 thready qty per inch (tpi), maximum continuous load current rating per pole: 2.5 amperes ac single location.
Manufacturer part number 65A139D92 for national stock number 5925001323607.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-132-3607.
-
MPN or Model
65A139D92
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Case Material
Metal -
Pole Quantity
1 -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
2.5 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
750.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Reset -
Thread Size
0.375 inches -
Inclosure Protection Type For Which Designed
Explosion proof -
Thread Series Designator
Unef -
Terminal Type And Quantity
2 wire hook
More from these suppliers
- 5950-00-071-3614 MPN 694824Power Transformer
- 5905-00-071-5891 MPN 2316873Nonprecision Wire Wound Variable Resistor
- 5940-00-103-0229 MPN 2437483Computer Terminal
- 5950-00-151-4544 MPN 2678618Power Transformer
- 5905-00-153-8235 MPN 2877116Precision Wire Wound Variable Resistor
- 5985-00-163-3979 MPN 2116071Waveguide Assembly
- 5905-00-226-9555 MPN 588426PC35Noninductive Wire Wound Fixed Resistor
- 5935-00-258-4134 MPN LD476833Electrical Receptacle Connector
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-132-3607 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
65A139D92 | Navair And Navsea Managed |
65A139D92 | Naval Air Systems Command |
SM3-2-5 | Eaton Corp |
Stock Check
![](/public/images/partscage_shelf3.png)