NSN 5925-00-133-5365
Overload Switch
Multipole-multiple actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number A15912-004 for national stock number 5925001335365.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-133-5365.
-
MPN or Model
A15912-004
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Body Length
2.530 inches -
Body Width
3.060 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.940 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.750 inches and 0.770 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.050 inches and 2.070 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.750 inches and 0.770 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.150 inches -
Mounting Surface To Terminal End Distance
2.522 inches -
Pole Quantity
4 -
Mounting Facility Type And Quantity
8 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay first location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
4 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
Two, three, and four linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip third location -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole three -
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 at 200 pct third location and 5.000 at 200 pct third location -
Inclosure Protection Type For Which Designed
Moisture resistant and fungus resistant and vibration resistant and shock resistant and explosion proof -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc -
Switch Voltage Rating And Type In Volts
125.0 ac and 50.0 dc -
Frequency In Hertz
400.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
10 threaded stud -
Specification Data
12436-a15912 government specification
More from these suppliers
- 5950-00-201-0113 MPN 666230-349Radio Frequency Coil
- 5940-00-552-4687 MPN 652107-000Feedthru Terminal
- 5935-01-183-6717 MPN PL2117099-008Electrical Plug Connector
- 5935-01-391-8035 MPN 6011996-473Electrical Connector Backshell
- 5950-00-203-1225 MPN 809000-284Radio Frequency Transformer
- 5930-00-932-3134 MPN A16138-014Rotary Switch
- 5905-01-535-7783 MPN 6012283-038Film Fixed Chip Resistor
- 5950-00-081-2144 MPN 666163-068Radio Frequency Transformer
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-133-5365 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
A15912-004 | Bae Systems Information And |
73-115-4MG6-10-250VAC400-16 | Eaton Corp |
Stock Check
![](/public/images/partscage_shelf3.png)