NSN 5925-00-139-2677
Overload Switch
Multipole-single actuator type body style, 0.188 inches mounting slot width, plastic case material, fragility factor: moderately rugged.
Manufacturer part number TED124050WL for national stock number 5925001392677.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-139-2677.
-
MPN or Model
TED124050WL
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
2.7 lb -
Body Style
Multipole-single actuator type -
Mounting Slot Width
0.188 inches -
Body Length
6.312 inches -
Body Width
2.750 inches -
Body Height
3.187 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
5.250 inches -
Center To Center Distance Between Terminals Parallel To Width
1.375 inches -
Unthreaded Mounting Hole Diameter
0.188 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.880 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.572 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.125 inches -
Pole Quantity
2 -
Arc Quenching Method
Deion -
Mounting Facility Type And Quantity
4 slot and 2 unthreaded hole -
Storage Type
General purpose warehouse -
Cubic Measure
55.319 cubic inches -
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac and 50.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac and 250.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
14000.0 ac and 10000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Instantaneous and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.900 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant -
Trip Release Ambient Tempurature Rating
50.0 degrees celsius all locations -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
4 compression
More from these suppliers
- 5925-01-008-3140 MPN THQP115Circuit Breaker
- 5925-01-170-4019 MPN 695C104G1-250V-25000AReverse Curr Cutout
- 5925-01-392-0877 MPN SEDA24T0030Circuit Breaker
- 5925-01-394-3718 MPN TFKSTA12RSCircuit Breaker Subassembly
- 5925-01-433-9512 MPN TED134060/TEDAS2ASB1RBCircuit Breaker
- 5925-01-437-8345 MPN 343L747G33Circuit Breaker Tripper
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-139-2677 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
TED124050WL | General Electric Co |