1-321-802-5889

NSN 5925-00-164-2084

Overload Switch

About this product

Single pole type body style, 0.178 inches mounting slot width, plastic case material, fragility factor: moderately rugged.

Manufacturer part number CD1B375-3 for national stock number 5925001642084.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-00-164-2084.

  • MPN or Model

    CD1B375-3

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    0.8 lb
  • Body Style
    Single pole type
  • Mounting Slot Width
    0.178 inches
  • Body Length
    Between 5.790 inches and 5.810 inches
  • Body Width
    Between 1.016 inches and 1.036 inches
  • Body Height
    Between 2.257 inches and 2.277 inches
  • Case Material
    Plastic
  • Unthreaded Mounting Hole Diameter
    0.164 inches
  • Fragility Factor
    Moderately rugged
  • Boss Height
    Between 0.209 inches and 0.229 inches
  • Pole Quantity
    1
  • Arc Quenching Method
    Magnetic blowout
  • Mounting Facility Type And Quantity
    2 threaded hole and 1 unthreaded hole and 1 slot
  • Storage Type
    General purpose warehouse
  • Thready Qty Per Inch (tpi)
    32
  • Maximum Continuous Load Current Rating Per Pole
    75.0 amperes dc single location
  • Operating Voltage Type And Rating Per Pole In Volts
    125.0 dc single location
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    5000.0 dc single location
  • Circuit Protection Type
    Overcurrent single location
  • Trip Release Method
    Magnetic-hydraulic single location
  • Trip Release Characteristic
    Time delay single location
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    125.0 single location
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole one
  • Internal Trip Release Configuration
    Series trip single location
  • Thread Size
    0.138 inches
  • Trip Delay Time In Seconds Per Rated Continuous Current
    0.150 at 200 pct single location and 0.700 at 200 pct single location
  • Inclosure Protection Type For Which Designed
    Fungus resistant and moisture resistant
  • Thread Series Designator
    Unc
  • Terminal Type And Quantity
    2 screw
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-00-164-2084 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925001642084

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
CD1B375-3 Eaton Corp
299-1-3740-2 Airpax Electronics Div Of North
37865-2 Evoqua Water Technologies Llc
CD1-B3-75-125-3 Eaton Corp
A2T91710 Evoqua Water Technologies Llc
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.