NSN 5925-00-166-8290
Overload Switch
Plastic case material, 3 poles, 100.0 amperes ac all locations maximum continuous load current rating per pole, operating voltage type and rating per pole in volts: 240.0 ac all locations.
Manufacturer part number CHB3100 for national stock number 5925001668290.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-166-8290.
-
MPN or Model
CHB3100
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.9 lb -
Body Length
6.000 inches -
Body Width
2.219 inches -
Body Height
2.530 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Width
0.739 inches -
Boss Height
0.188 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
3 terminal -
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Trip Delay Time In Seconds Per Rated Continuous Current
360.000 at 200 pct all locations -
Trip Release Ambient Tempurature Rating
40.0 degrees celsius all locations -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
3 clip and 3 compression
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-166-8290 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
CHB3100 | Eaton Corp |