NSN 5925-00-173-7650
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number CA2 for national stock number 5925001737650.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-173-7650.
-
MPN or Model
CA2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Overall Length
2.000 inches -
Body Width
1.343 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
0.906 inches -
Unthreaded Mounting Hole Diameter
0.250 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.574 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.234 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 unthreaded hole -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac single location and 2.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
110.0 ac single location and 30.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
575.0 ac single location and 875.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 single location -
Reset Method
Automatic -
Internal Trip Release Configuration
Series trip single location -
Trip Delay Time In Seconds Per Rated Continuous Current
5.000 at 200 pct single location and 55.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
General purpose -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location -
Frequency In Hertz
60.0 single location -
Unpackaged Unit Weight
1.000 ounces -
Terminal Type And Quantity
2 tab w/screw
More from these suppliers
- 5930-01-147-5838 MPN 26PSI100RC425K-325KPressure Switch
- 5930-00-133-1576 MPN 4286A1-88Thermostatic Switch
- 5930-00-936-5944 MPN 3BTL6-41Thermostatic Switch
- 5930-01-155-9875 MPN C4391513-25Thermostatic Switch
- 5930-01-254-3811 MPN C4344-195-9555Thermostatic Switch
- 5935-01-341-2290 MPN FL0733-92-24Electrical Receptacle Connector
- 5930-01-423-1028 MPN M221F162030582Thermostatic Switch
- 5930-01-145-4097 MPN 7BTL3A-7Thermostatic Switch
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.