NSN 5925-00-174-3340
Overload Switch
Multipole-single actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 2.
Manufacturer part number P2263SMG4-0-5-250VAC60 for national stock number 5925001743340.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-174-3340.
-
MPN or Model
P2263SMG4-0-5-250VAC60
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Body Length
Between 5.240 inches and 5.260 inches -
Body Width
Between 1.990 inches and 2.010 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 4.349 inches and 4.369 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.990 inches and 1.010 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 3.052 inches and 3.072 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.990 inches and 1.010 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.209 inches and 0.229 inches -
Mounting Surface To Terminal End Distance
Between 3.303 inches and 3.323 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Instantaneous all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
120.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
Between pole one and two -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Frequency In Hertz
60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 threaded stud
More from these suppliers
- 5925-00-345-6197 MPN AM33MG6-10-120-15-400Circuit Breaker
- 5925-00-369-7747 MPN HB1Z2-106Circuit Breaker
- 5925-00-910-3594 MPN AM1B2-1A12VDPCCircuit Breaker
- 5925-01-020-7323 MPN XAM33MG350125AC5Circuit Breaker
- 5925-01-037-6876 MPN HE3C2-9-2Circuit Breaker
- 5925-01-043-3151 MPN 53-121-6-MG3Circuit Breaker
- 5925-01-114-5183 MPN 70-377-44-MG6Circuit Breaker
- 5925-01-145-5330 MPN AM4-Z108-1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-174-3340 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
P2263SMG4-0-5-250VAC60 | Eaton Corp |
P2263SM6-0-50 | Eaton Corp |