NSN 5925-00-175-2600
Overload Switch
Plastic case material, 1 poles, 32 thready qty per inch (tpi), maximum continuous load current rating per pole: 70.0 amperes dc single location.
Manufacturer part number 1628A81224 for national stock number 5925001752600.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-175-2600.
-
MPN or Model
1628A81224
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Case Material
Plastic -
Pole Quantity
1 -
Mounting Facility Type And Quantity
2 threaded hole -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
70.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
31.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Dustproof -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 screw
More from these suppliers
- 1560-00-053-2244 MPN 53-11026-2Aircraft Structural Panel
- 1560-00-443-7574 MPN 272T6040012-001Small Arms-fragmentation Protective Supplemental Armor
- 6145-00-295-2812 MPN MMSE052-16-9Electrical Wire
- 5940-00-539-2203 MPN V3Terminal Board
- 5945-01-196-4631 MPN 2160B220HA22-42MOD AElectromagnetic Relay
- 5930-01-213-6519 MPN H33SS1-2MRDB1Switch Subassembly
- 5930-01-308-5118 MPN ZB2-BS54Push Button
- 5945-01-441-0370 MPN FCP34015TF1073Electromagnetic Relay
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-175-2600 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
1628A81224 | Lockheed Martin Corporation |
9301-70B | Schneider Electric Usa, Inc. |