NSN 5925-00-185-4020
Overload Switch
Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number 260-1014-050 for national stock number 5925001854020.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-185-4020.
-
MPN or Model
260-1014-050
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.3 lb -
Thread Pitch Diameters
+0.1177/+0.1214 inches -
Body Style
Multipole-multiple actuator type -
Body Length
Between 2.490 inches and 2.510 inches -
Body Width
Between 2.240 inches and 2.260 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.928 inches and 1.948 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.740 inches and 0.760 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.052 inches and 2.072 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.740 inches and 0.760 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.130 inches and 0.150 inches -
Mounting Surface To Terminal End Distance
Between 2.689 inches and 2.813 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
2.200 at 200 pct all locations and 20.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Frequency In Hertz
60.0 all locations -
Test Data Document
81349-mil-c-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud -
Specification Data
81349-mil-c-55629/5 government specification
More from these suppliers
- 5905-00-065-4453 MPN 7233724P001Thermal Resistor
- 5950-00-251-4371 MPN M7466143REV2Power Transformer
- 5945-00-781-7229 MPN 77C700716P001Electromagnetic Relay
- 5930-00-936-5944 MPN 7237736P001Thermostatic Switch
- 5950-00-997-2810 MPN 77C708629-1Power Transformer
- 5935-01-231-6844 MPN 77C717595P001Connector
- 5935-01-257-0115 MPN 77C721852P001Electrical Receptacle Connector
- 5985-01-279-3757 MPN 73163220P005Waveguide Assembly
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-185-4020 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
260-1014-050 | Rockwell Collins, Inc. |
APL111-1-62-203-M | Sensata Technologies Maryland, Inc |
XAM33M6-20 | Eaton Corp |
AM3-Z29-101 | Eaton Corp |
AM333-20-125-4-60 | Eaton Corp |
M55629/5-101 | Military Specifications |
MIL-C-55629/5 | Military Specifications |
7727721P009 | Lockheed Martin Corporation |
APL111-55629-5-101 | Sensata Technologies Maryland, Inc |
7727721P009 | General Electric Co |
632237-136 | Lockheed Martin Corporation |
AM333MG6-20-250-4-60 | Eaton Corp |
AM333MG3-20-250AC60-4 | Eaton Corp |
AM333MG6-20-250VAC60C4 | Eaton Corp |
220-220-101 | Wood Electric Operations Potter And |