NSN 5925-00-189-4319
Overload Switch
Single pole type body style, metal case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number SM-A-569574-83 for national stock number 5925001894319.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-189-4319.
-
MPN or Model
SM-A-569574-83
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Thread Pitch Diameters
+0.3503/+0.3537 inches -
Body Style
Single pole type -
Bushing Length
0.375 inches -
Body Length
1.479 inches -
Body Width
0.598 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.875 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.555 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location -
Ultimate Trip Time Per Pole In Seconds
6.500 all locations and 30.000 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.375 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 at 200 pct all locations and 4.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Explosion resistant and hermetically sealed -
Frequency In Hertz
400.0 single location -
Unpackaged Unit Weight
2.100 ounces -
Thread Series Designator
Unef -
Terminal Type And Quantity
2 wire hook
More from these suppliers
- 5925-00-182-7452 MPN AM1-Z21-128Circuit Breaker
- 5925-00-190-0093 MPN 2XAM1516MG3-20-250-2-50Circuit Breaker
- 5925-00-299-7809 MPN 50-309MG3-30Circuit Breaker
- 5925-00-336-1989 MPN JC3-A3-15-2Circuit Breaker
- 5925-00-566-4169 MPN AM12-25-32VDC4Circuit Breaker
- 5925-00-758-7955 MPN 2XAM17-10-32VDC56Circuit Breaker
- 5925-00-800-0021 MPN AM13HKMG3-0.50-115-60-5Circuit Breaker
- 5925-00-836-4574 MPN AM12HKMG3-10-0-23Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-189-4319 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
SM-A-569574-83 | Us Army Communications & |
AP1-3-42-302 | Sensata Technologies Maryland, Inc |
SM5-3-250-400-1 | Eaton Corp |