NSN 5925-00-190-0093
Overload Switch
Plastic case material, 2 poles, 32 thready qty per inch (tpi), maximum continuous load current rating per pole: 20.0 amperes ac all locations.
Manufacturer part number 2XAM1516MG3-20-250-2-50 for national stock number 5925001900093.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-190-0093.
-
MPN or Model
2XAM1516MG3-20-250-2-50
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Length
3.719 inches -
Body Width
2.031 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.063 inches -
Center To Center Distance Between Terminals Parallel To Width
1.031 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.031 inches -
Boss Height
0.156 inches -
Mounting Surface To Terminal End Distance
3.429 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
4 threaded hole -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Ultimate Trip Time Per Pole In Seconds
11.000 all locations and 80.000 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
10.300 at 150 pct all locations and 40.000 at 150 pct all locations and 2.000 at 300 pct all locations and 6.000 at 300 pct all locations and 1.000 at 400 pct all locations and 3.000 at 400 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Frequency In Hertz
50.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 threaded stud
More from these suppliers
- 5925-00-001-5914 MPN 3363-20AMPCircuit Breaker
- 5925-00-055-9371 MPN AM17-5-120-50-60-55Circuit Breaker
- 5925-00-151-9684 MPN 0322-30ACircuit Breaker
- 5925-00-201-0963 MPN AM333MG6-30-250VAC60C5Circuit Breaker
- 5925-00-409-3621 MPN AM33-20-250-60-4Circuit Breaker
- 5925-00-587-4154 MPN XAM33MG3-1.154-115-5-60Circuit Breaker
- 5925-00-683-1638 MPN 3XAM1516MG3-20-416VACCURVE12Circuit Breaker
- 5925-00-790-3799 MPN AM12HKMG3-10-0-50-250VAC4Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-190-0093 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
2XAM1516MG3-20-250-2-50 | Eaton Corp |