NSN 5925-00-190-0095
Overload Switch
Multipole-single actuator type body style, plastic case material, 3 poles, thready qty per inch (tpi): 32.
Manufacturer part number 3XAM1516MG3-50-120-2-400 for national stock number 5925001900095.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-190-0095.
-
MPN or Model
3XAM1516MG3-50-120-2-400
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Style
Multipole-single actuator type -
Body Length
3.719 inches -
Body Width
3.052 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.063 inches -
Center To Center Distance Between Terminals Parallel To Width
1.031 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.031 inches -
Boss Height
0.156 inches -
Mounting Surface To Terminal End Distance
3.359 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
6 threaded hole -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Ultimate Trip Time Per Pole In Seconds
11.000 all locations and 70.000 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
4.500 at 200 pct all locations and 10.700 at 200 pct all locations and 0.700 at 400 pct all locations and 1.100 at 400 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Frequency In Hertz
400.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5925-00-078-1705 MPN 64-180-2Circuit Breaker
- 5925-00-081-4534 MPN PAM1510HKMG3-7-28Circuit Breaker
- 5925-00-088-9506 MPN 70-761K15AMPCircuit Breaker
- 5925-00-108-5385 MPN AM12MG6-5-32VDCCURVE4Circuit Breaker
- 5925-00-161-9167 MPN AM12-15-115-60-4Circuit Breaker
- 5925-00-274-3195 MPN AM333MG6-25-250 60-4Circuit Breaker
- 5925-00-360-2399 MPN AM33MG-50.0-5-250-60Circuit Breaker
- 5925-00-455-8584 MPN AM17-15-120-55-60Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-190-0095 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
3XAM1516MG3-50-120-2-400 | Eaton Corp |
Stock Check