NSN 5925-00-236-5274
Overload Switch
Multipole-multiple actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number 260-4016-290 for national stock number 5925002365274.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-236-5274.
-
MPN or Model
260-4016-290
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Body Length
Between 5.240 inches and 5.260 inches -
Body Width
Between 4.490 inches and 4.510 inches -
Body Height
Between 2.677 inches and 2.697 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 4.349 inches and 4.369 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.990 inches and 1.010 inches -
Unthreaded Mounting Hole Diameter
0.190 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 3.052 inches and 3.072 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.990 inches and 1.010 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.208 inches and 0.228 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
12 threaded hole and 12 unthreaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.164 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
5.500 at 200 pct all locations and 20.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Dustproof and fungus proof -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
15.0 ac and 0.25 dc -
Switch Voltage Rating And Type In Volts
460.0 ac and 250.0 dc -
Frequency In Hertz
400.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 compression
More from these suppliers
- 5905-00-052-0313 MPN 710-3642-000Inductive Wire Wound Fixed Resistor
- 5935-00-078-7358 MPN 764-8017-002Electrical Connector Bracket
- 5950-00-086-8798 MPN 240-1099-00Radio Frequency Coil
- 5905-00-114-2853 MPN 745-1116-000Composition Fixed Resistor
- 5905-00-116-8561 MPN 745-1285-000Composition Fixed Resistor
- 5950-00-144-0535 MPN 278-0008-00Radio Frequency Transformer
- 5940-00-147-1225 MPN 372-2210-00Electrical Binding Post
- 5905-00-196-1158 MPN 749-4728-050Nonprecision Wire Wound Variable Resistor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-236-5274 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
260-4016-290 | Rockwell Collins, Inc. |
3X1163SVHKMG4-50AMP250V400C12 | Eaton Corp |
64-174-2MG4 | Eaton Corp |
3X1163SVHKMG4-50AMP250V400C2 | Eaton Corp |
Stock Check