1-321-802-5889

NSN 5925-00-238-0412

Overload Switch

About this product

Multipole-multiple actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.

Manufacturer part number 10670787-4 for national stock number 5925002380412.

Picture of NSN 5925-00-238-0412 Picture of NSN 5925-00-238-0412 Picture of NSN 5925-00-238-0412

Datasheet

  • Product description

    Circuit Breaker NSN 5925-00-238-0412.

  • MPN or Model

    10670787-4

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    1 lb
  • Body Style
    Multipole-multiple actuator type
  • Body Length
    2.500 inches
  • Body Width
    2.295 inches
  • Case Material
    Plastic
  • Center To Center Distance Between Terminals Parallel To Length
    1.940 inches
  • Center To Center Distance Between Terminals Parallel To Width
    0.750 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
    2.060 inches
  • Switch Contact Arrangement
    Single pole, double throw
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
    0.750 inches
  • Fragility Factor
    Moderately rugged
  • Boss Height
    0.150 inches
  • Mounting Surface To Terminal End Distance
    2.927 inches
  • Pole Quantity
    3
  • Mounting Facility Type And Quantity
    6 threaded hole
  • Storage Type
    General purpose warehouse
  • Special Handling Feature
    Magnetic
  • Thready Qty Per Inch (tpi)
    32
  • Maximum Continuous Load Current Rating Per Pole
    30.0 amperes ac all locations
  • Operating Voltage Type And Rating Per Pole In Volts
    416.0 ac all locations
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    408.0 ac all locations
  • Circuit Protection Type
    Overcurrent all locations
  • Trip Release Method
    Magnetic-hydraulic all locations
  • Trip Release Characteristic
    Time delay all locations
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    150.0 all locations
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    3 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At each pole
  • External Actuator Linkage Arrangement
    One, two, and three linked
  • Auxiliary Switch Function And Quantity
    1 alarm
  • Internal Trip Release Configuration
    Series trip all locations
  • Thread Size
    0.138 inches
  • Switch Location And Position Designation
    Internal at pole three
  • Trip Delay Time In Seconds Per Rated Continuous Current
    2.000 at 200 pct all locations and 9.000 at 200 pct all locations
  • Inclosure Protection Type For Which Designed
    Fungus resistant and moisture resistant
  • Switch Terminal Type
    Tab, solder lug
  • Switch Current Rating And Type In Amps
    5.0 ac and 1.0 dc
  • Switch Voltage Rating And Type In Volts
    125.0 ac and 50.0 dc
  • Frequency In Hertz
    400.0 all locations
  • Unpackaged Unit Weight
    0.600 pounds
  • Test Data Document
    18876-10670787 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
  • Thread Series Designator
    Unc
  • Terminal Type And Quantity
    6 threaded stud
More from these suppliers
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-00-238-0412 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925002380412

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
10670787-4 U S Army Aviation And Missile
10670787-4 Raytheon Company
295-111-1RE-2343-4 Sensata Technologies Maryland, Inc
72-282-4MG6 Eaton Corp
10670787-4 Raytheon Company
10670787-4 Raytheon Company
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.