NSN 5925-00-243-5869
Overload Switch
Plastic case material, 3 poles, 125.0 amperes ac all locations maximum continuous load current rating per pole, operating voltage type and rating per pole in volts: 240.0 ac all locations.
Manufacturer part number TQD32125WL for national stock number 5925002435869.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-243-5869.
-
MPN or Model
TQD32125WL
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
4.2 lb -
Case Material
Plastic -
Unthreaded Mounting Hole Diameter
0.190 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
4 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
125.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Internal Trip Release Configuration
Series trip all locations -
Trip Delay Time In Seconds Per Rated Continuous Current
75.000 at 200 pct all locations and 350.000 at 200 pct all locations -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
6 screw
More from these suppliers
- 5975-00-632-4323 MPN 7488977G2High Voltage Grounding Rod
- 5930-01-440-9424 MPN 080XPLRSPush Switch
- 5925-00-244-0711 MPN TEB132070WL/TE100SCircuit Breaker
- 5925-00-997-8234 MPN TED136100WLCircuit Breaker
- 5925-01-392-0881 MPN SGLA36AI0600Circuit Breaker
- 5925-01-536-0165 MPN TED134040WL,TEDAS2AB1RCircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-243-5869 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
TQD32125WL | General Electric Co |