NSN 5925-00-246-4645
Overload Switch
Plastic case material, 2 poles, 25.0 amperes ac all locations maximum continuous load current rating per pole, operating voltage type and rating per pole in volts: 125.0 ac all locations.
Manufacturer part number SK3375 for national stock number 5925002464645.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-246-4645.
-
MPN or Model
SK3375
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.4 lb -
Case Material
Plastic -
Unthreaded Mounting Hole Diameter
0.156 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
2 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Internal Trip Release Configuration
Series trip all locations -
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 at 250 pct all locations -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius all locations -
Terminal Type And Quantity
4 screw
More from these suppliers
- 5905-00-299-1819 MPN PX1-2-5Inductive Wire Wound Fixed Resistor
- 5945-01-183-6524 MPN 31063-589-50Relay Kit
- 5930-01-245-4742 MPN 9001KQ-14BSwitch Subassembly
- 5930-01-299-6318 MPN 9001-D4V1GSC01M01Push Switch
- 5930-00-584-4503 MPN 9007B52B2Sensitive Switch
- 6110-01-287-1434 MPN 8903-SPG2Magnetic Contactor
- 5925-00-402-1162 MPN KAL36150Circuit Breaker
- 5925-01-107-0844 MPN LA-36400Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-246-4645 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
SK3375 | Square D Co |
SK3375 | Schneider Electric Usa, Inc. |
SK3375 | Square D Co |
SK3375 | Schneider Electric Usa, Inc. |
SK3375 | Square D Co |
SK3375 | Schneider Electric Usa, Inc. |
SK3375 | Square D Co |
SK3375 | Schneider Electric Usa, Inc. |
SK3375 | Square D Co |
SK3375 | Schneider Electric Usa, Inc. |
SK3375 | Square D Co |
SK3375 | Schneider Electric Usa, Inc. |
SK3375 | Schneider Electric Usa, Inc. |
SK3375 | Square D Co |
SK3375 | Square D Co |
SK3375 | Schneider Electric Usa, Inc. |
SK3375 | Square D Co |
SK3375 | Schneider Electric Usa, Inc. |
SK3375 | Square D Co |
SK3375 | Schneider Electric Usa, Inc. |
SK3375 | Square D Co |
SK3375 | Schneider Electric Usa, Inc. |