NSN 5925-00-247-6979
Overload Switch
Plastic case material, single pole, double throw switch contact arrangement, moderately rugged fragility factor, pole quantity: 4.
Manufacturer part number 11152623 for national stock number 5925002476979.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-247-6979.
-
MPN or Model
11152623
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.5 lb -
Body Length
Between 2.490 inches and 2.510 inches -
Body Width
Between 2.990 inches and 3.010 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.928 inches and 1.948 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.740 inches and 0.760 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.052 inches and 2.072 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.740 inches and 0.760 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.130 inches and 0.150 inches -
Mounting Surface To Terminal End Distance
Between 2.461 inches and 2.481 inches -
Pole Quantity
4 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
8 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac third location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
4 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, three, and four linked -
Auxiliary Switch Function And Quantity
1 control -
Internal Trip Release Configuration
Series trip third location -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
8.000 at 300 pct all locations and 25.000 at 300 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
2.5 ac and 1.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc -
Frequency In Hertz
400.0 all locations -
Unpackaged Unit Weight
14.000 ounces -
Test Data Document
18876-11152623 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing) -
Thread Series Designator
Unc -
Terminal Type And Quantity
10 threaded stud
More from these suppliers
- 5935-00-082-0481 MPN 9198305Electrical Receptacle Connector
- 5985-00-106-7062 MPN 10658186Variable Attenuator
- 5905-00-344-2552 MPN 8191914Inductive Wire Wound Fixed Resistor
- 5940-00-543-8300 MPN 9057278Terminal Board
- 5940-00-553-2782 MPN 8034556-10Grounding Metallic Shielded Cable Ferrule
- 5935-00-577-8713 MPN 10033230-71Electrical Receptacle Connector
- 5905-00-655-2969 MPN 9166212Nonprecision Wire Wound Variable Resistor
- 5930-00-677-2381 MPN 9171929Rotary Switch
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability