NSN 5925-00-283-8139
Overload Switch
Metal case material, 3 poles, 75.0 amperes dc all locations maximum continuous load current rating per pole, operating voltage type and rating per pole in volts: 355.0 dc all locations.
Manufacturer part number 13346 for national stock number 5925002838139.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-283-8139.
-
MPN or Model
13346
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Case Material
Metal -
Unthreaded Mounting Hole Diameter
0.438 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
4 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
75.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
355.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
1400.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip w/separate reset -
Auxiliary Switch Function And Quantity
1 control -
Terminal Type And Quantity
6 threaded stud -
Reference Number Differentiating Characteristics
As differentiated by pole quantity, macimum continuous loadcurrent rating, operating voltage type and rating
More from these suppliers
- 5905-01-371-1244 MPN 740420PC22Inductive Wire Wound Fixed Resistor
- 5930-01-453-5812 MPN 746607-K01Switch Latch
- 5905-01-494-4261 MPN 703880PC1361Inductive Wire Wound Fixed Resistor
- 5950-01-494-8561 MPN 179598BElectrical Coil
- 5925-00-583-5020 MPN ETN4840Circuit Breaker Subassembly
- 5925-00-628-7784 MPN ETN7730Circuit Breaker Tripper
- 5925-01-170-4132 MPN 710600-711750Circuit Breaker
- 5925-01-233-5632 MPN 704060AND707831Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-283-8139 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
13346 | Spd Electrical Systems, Inc |
S13346 | Spd Electrical Systems, Inc |
S6205-3137327 | Naval Ship Systems Command |