NSN 5925-00-284-2713
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number 266-0021-00 for national stock number 5925002842713.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-284-2713.
-
MPN or Model
266-0021-00
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
Between 3.709 inches and 3.729 inches -
Body Width
Between 0.980 inches and 1.000 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 3.053 inches and 3.073 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.740 inches and 2.760 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.146 inches and 0.166 inches -
Mounting Surface To Terminal End Distance
3.239 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
230.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.180 at 200 pct single location and 0.500 at 200 pct single location -
Inclosure Protection Type For Which Designed
Dustproof and fungus proof -
Frequency In Hertz
60.0 single location -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5905-00-005-2902 MPN 724-0640-360Film Fixed Resistor
- 5905-00-034-0073 MPN 745-3401-000Composition Fixed Resistor
- 5905-00-082-9962 MPN 747-0225-00Inductive Wire Wound Fixed Resistor
- 5950-00-086-8711 MPN 678-0048-000Reactor
- 5950-00-086-8787 MPN 674-5038-00Saturable Reactor
- 5905-00-482-0978 MPN 381-1721-030Nonprecision Wire Wound Variable Resistor
- 5945-00-483-5995 MPN 974-0449-009Electromagnetic Relay
- 5950-00-504-9808 MPN 541-0801-003Radio Frequency Transformer
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-284-2713 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
266-0021-00 | Rockwell Collins, Inc. |
50-260AMB10-20-230-115VAC3 | Eaton Corp |