NSN 5925-00-317-9985
Overload Switch
Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 2.
Manufacturer part number APL11-1-51-153 for national stock number 5925003179985.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-317-9985.
-
MPN or Model
APL11-1-51-153
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Thread Pitch Diameters
+0.1177/+0.1214 inches -
Body Style
Multipole-multiple actuator type -
Body Length
2.510 inches -
Body Width
Between 1.437 inches and 1.563 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.660 inches and 1.960 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.719 inches and 0.781 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.046 inches and 2.078 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.719 inches and 0.781 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.109 inches and 0.171 inches -
Mounting Surface To Terminal End Distance
2.553 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.130 at 200 pct all locations and 1.400 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Shock resistant and vibration resistant -
Test Data Document
81349-mil-c-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 threaded stud -
Specification Data
81349-mil-c-55629/3 government specification
More from these suppliers
- 5905-00-004-5832 MPN MILR22097-5Nonprecision Nonwire Wound Variable Resistor
- 5905-00-004-5833 MPN RTR24DX201MNonprecision Wire Wound Variable Resistor
- 5905-00-004-6054 MPN RER60F33R2RInductive Wire Wound Fixed Resistor
- 5905-00-004-6058 MPN RER65F4R87MInductive Wire Wound Fixed Resistor
- 5930-00-005-2501 MPN M3786/13-0027Rotary Switch
- 5905-00-005-2663 MPN RBR71L36061BRNoninductive Wire Wound Fixed Resistor
- 5905-00-005-8911 MPN RNC60C1822FRFilm Fixed Resistor
- 5935-00-009-6303 MPN M83723/72R2212NElectrical Receptacle Connector
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-317-9985 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
APL11-1-51-153 | Sensata Technologies Maryland, Inc |
APL11-1-51-153-M | Sensata Technologies Maryland, Inc |
M55629/3-093 | Military Specifications |
MIL-PRF-55629/3 | Military Specifications |
APL11-55629-3-093 | Sensata Technologies Maryland, Inc |
MIL-C-55629/3 | Military Specifications |
Stock Check
![](/public/images/partscage_shelf3.png)