NSN 5925-00-351-6285
Overload Switch
Fluorescent button ring.
Manufacturer part number 49B6768 for national stock number 5925003516285.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-351-6285.
-
MPN or Model
49B6768
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Overall Length
2.188 inches -
Overall Height
2.000 inches -
Overall Width
0.750 inches -
Case Material
Plastic -
Pole Quantity
1 -
Mounting Facility Type And Quantity
Thd bushing -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac single location and 10.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
15.0 ac single location and 28.0 dc single location and 30.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3000.0 ac single location and 3000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push-pull -
Actuator Function
Trip-reset -
Trip Delay Time In Seconds Per Rated Continuous Current
600.000 at 150 pct single location and 15.000 at 200 pct single location and 45.000 at 200 pct single location and 6.000 at 300 pct single location -
Inclosure Protection Type For Which Designed
Explosion proof -
Trip Release Ambient Tempurature Rating
40.0 degrees celsius single location -
Terminal Type And Quantity
2 screw
More from these suppliers
- 5930-00-488-6779 MPN 9013FSG-2PPressure Switch
- 5925-01-499-6003 MPN FCP34100-1394Circuit Breaker
- 5925-01-565-4642 MPN 25418Circuit Breaker
- 5305-00-398-4961 MPN 50B7952-2Jack Platform Screw
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-351-6285 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
49B6768 | Department Of The Air Force |
9020C | Schneider Electric Usa, Inc. |