NSN 5925-00-379-0920
Overload Switch
Rectangular dimensional envelope body style, plastic case material, 1 poles, storage type: general purpose warehouse.
Manufacturer part number 1375D81G06 for national stock number 5925003790920.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-379-0920.
-
MPN or Model
1375D81G06
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Rectangular dimensional envelope -
Overall Length
6.000 inches -
Overall Height
1.375 inches -
Overall Width
3.969 inches -
Case Material
Plastic -
Unthreaded Mounting Hole Diameter
0.188 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
2 unthreaded hole -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac single location and 35.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 125.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location and 5000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip w/separate reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Trip Delay Time In Seconds Per Rated Continuous Current
80.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Fungus resistant -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location -
Frequency In Hertz
60.0 single location -
Terminal Type And Quantity
2 screw
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-379-0920 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
1375D81G06 | Westinghouse Air Brake Technologies |
1532379 | Westinghouse Air Brake Technologies |
Stock Check
![](/public/images/partscage_shelf3.png)