NSN 5925-00-399-5980
Overload Switch
Luminescent red band visiblein trip position.
Manufacturer part number 49B6768-15 for national stock number 5925003995980.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-399-5980.
-
MPN or Model
49B6768-15
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Overall Length
2.188 inches -
Overall Height
2.688 inches -
Overall Width
0.750 inches -
Pole Quantity
1 -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1200.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 push-pull -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 at 200 pct single location and 100.000 at 200 pct single location and 10.000 at 400 pct single location and 3600.000 at 138 pct single location -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location -
Frequency In Hertz
400.0 single location -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 screw
More from these suppliers
- 5935-00-222-7319 MPN 1628A81286Receptacle Dummy Connector
- 5985-00-987-3864 MPN 293BC700057-001Variable Attenuator
- 5306-00-297-8521 MPN 272-4700071Shoulder Bolt
- 4820-00-348-2164 MPN 53A3516Valve Cap
- 5305-00-150-9216 MPN AC503-10-24Machine Screw
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-399-5980 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
49B6768-15 | Department Of The Air Force |
E763100-5 | Lockheed Martin Corporation |
72 | Mechanical Products Co |
Stock Check
![](/public/images/partscage_shelf3.png)