NSN 5925-00-401-7702
Overload Switch
Unlimited ac and dc interrupting current capacity.
Manufacturer part number 80P09907A002 for national stock number 5925004017702.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-401-7702.
-
MPN or Model
80P09907A002
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Body Style
Multipole-single actuator type -
Bushing Length
Between 0.219 inches and 0.281 inches -
Body Length
2.000 inches -
Body Width
0.850 inches -
Body Height
2.765 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
0.703 inches -
Center To Center Distance Between Terminals Parallel To Width
0.375 inches -
Nonturn Device Location
At 3 oclock and at 6 oclock and at 9 oclock and at 12 oclock -
Fragility Factor
Moderately rugged -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
1.5 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
145.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push-pull -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.469 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 at 200 pct all locations and 35.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Explosion proof and shock resistant and vibration resistant -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius all locations -
Frequency In Hertz
400.0 all locations -
Unpackaged Unit Weight
0.350 pounds -
Thread Series Designator
Uns -
Terminal Type And Quantity
6 tab w/screw
More from these suppliers
- 5905-00-405-8111 MPN 17P07903A001Inductive Wire Wound Fixed Resistor
- 5950-01-127-2818 MPN 24-P03683G008Power Autotransformer Transformer
- 5905-00-840-5774 MPN 217B250REV0PInductive Wire Wound Fixed Resistor
- 5930-00-254-2130 MPN M1185170232Thermostatic Switch
- 5930-01-078-9357 MPN M1-045-025-1-8-2Thermostatic Switch
- 5930-01-087-2016 MPN M1-230-200-142Thermostatic Switch
- 5930-01-445-9793 MPN 7BTL6A-10Thermostatic Switch
- 5930-01-094-6802 MPN 3BTL18-36Thermostatic Switch
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-401-7702 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
80P09907A002 | General Dynamics Mission Systems, |
7276-101-1 1/2 | Sensata Technologies, Inc |
80P09907A002 | Motorola Inc. |
Stock Check
![](/public/images/partscage_shelf3.png)