NSN 5925-00-408-8845
Overload Switch
Multipole-single actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number GB3-A2A3A3-20-9-60 for national stock number 5925004088845.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-408-8845.
-
MPN or Model
GB3-A2A3A3-20-9-60
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Body Length
Between 5.990 inches and 6.010 inches -
Body Width
Between 4.490 inches and 4.510 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 5.115 inches and 5.135 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 1.490 inches and 1.510 inches -
Unthreaded Mounting Hole Diameter
Between 0.256 inches and 0.276 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 4.583 inches and 4.603 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 1.490 inches and 1.510 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.177 inches and 0.197 inches -
Mounting Surface To Terminal End Distance
Between 4.427 inches and 4.447 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 unthreaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Switch Location And Position Designation
External at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
30.000 at 200 pct all locations and 250.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant and shock resistant and vibration resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
15.0 ac and 0.25 dc -
Switch Voltage Rating And Type In Volts
460.0 ac and 250.0 dc -
Frequency In Hertz
60.0 all locations -
Unpackaged Unit Weight
4.000 pounds -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5925-00-078-9566 MPN PAM1510NKMG3-13-200DC2Circuit Breaker
- 5925-00-081-9135 MPN 70-667MG3-24Circuit Breaker
- 5925-00-090-7403 MPN SM3HK0-5-50VDC2Circuit Breaker
- 5925-00-521-0389 MPN 86G2666B2Circuit Breaker
- 5925-00-755-5077 MPN 3XAM1516MG3-15AMP416VACTDC12Circuit Breaker
- 5925-00-810-8599 MPN AM12MG3-20-120VACSCircuit Breaker
- 5925-00-836-2393 MPN AM13CSKMG3-1-8Circuit Breaker
- 5925-00-915-0446 MPN AM333HK-10-208-3-60Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-408-8845 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
GB3-A2A3A3-20-9-60 | Eaton Corp |
GB3-A2A3A3-20-9 | Eaton Corp |
Stock Check
![](/public/images/partscage_shelf3.png)