NSN 5925-00-410-1722
Overload Switch
Plastic case material, 3 poles, 80.0 amperes ac all locations and 80.0 amperes dc all locations maximum continuous load current rating per pole, operating voltage type and rating per pole in volts: 480.0 ac all locations and 250.0 dc all locations.
Manufacturer part number NEF435080 for national stock number 5925004101722.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-410-1722.
-
MPN or Model
NEF435080
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Body Length
6.218 inches -
Body Width
4.125 inches -
Body Height
3.406 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
5.218 inches -
Center To Center Distance Between Terminals Parallel To Width
1.375 inches -
Unthreaded Mounting Hole Diameter
0.250 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
5.125 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches -
Boss Height
0.250 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
4 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
80.0 amperes ac all locations and 80.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac all locations and 250.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac all locations and 10000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Reset -
Actuator Position Designation
At pole two -
Trip Delay Time In Seconds Per Rated Continuous Current
25.000 at 200 pct all locations and 75.000 at 200 pct all locations and 5.100 at 300 pct all locations and 15.000 at 300 pct all locations -
Trip Release Ambient Tempurature Rating
40.0 degrees celsius all locations -
Frequency In Hertz
400.0 all locations -
Terminal Type And Quantity
6 compression
More from these suppliers
- 5930-00-840-1598 MPN 62-3-42-SB-1 PIECE 10Electrical Switch
- 5930-01-276-6169 MPN 504C323G04Disconnect Switch
- 5925-01-283-6897 MPN XJL433200Circuit Breaker
- 6110-01-288-7567 MPN DA86-02-105C-007Motor Starter
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-410-1722 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
NEF435080 | Challenger Electrical Equipment Corp |
NEF431080 | Challenger Electrical Equipment Corp |
Stock Check
![](/public/images/partscage_shelf3.png)