NSN 5925-00-410-7560
Overload Switch
Single pole type body style, metal case material, single pole, single throw, normally open switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number 10158805-2 for national stock number 5925004107560.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-410-7560.
-
MPN or Model
10158805-2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Body Style
Single pole type -
Bushing Length
Between 0.280 inches and 0.300 inches -
Body Length
Between 1.735 inches and 1.765 inches -
Body Width
Between 0.615 inches and 0.635 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
Between 1.225 inches and 1.255 inches -
Switch Contact Arrangement
Single pole, single throw, normally open -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
Between 1.623 inches and 1.653 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
32.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push-pull -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 control -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.469 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.100 at 200 pct single location and 2.000 at 200 pct single location -
Switch Terminal Type
Turret -
Switch Current Rating And Type In Amps
7.0 dc -
Switch Voltage Rating And Type In Volts
28.0 dc -
Thread Series Designator
Uns -
Terminal Type And Quantity
2 tab, solder lug
More from these suppliers
- 5935-00-034-3482 MPN 10179531Connector Adapter
- 5935-00-034-3558 MPN 10125453-5Electrical Connector Insert
- 5945-00-053-8963 MPN 10167374Electromagnetic Relay
- 5935-00-056-2475 MPN 10051783Plug-in Electronic Components Socket
- 5935-00-073-1957 MPN 10049237-5Electrical Plug Connector
- 5975-00-074-2072 MPN MIS17332-1-5Electrical Components Tiedown Strap
- 5935-00-084-8346 MPN 9742245-5Electrical Receptacle Connector Body
- 5940-00-159-1290 MPN 9976328-1Lug Terminal
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-410-7560 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
10158805-2 | U S Army Aviation And Missile |