NSN 5925-00-424-9298
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number NE114020 for national stock number 5925004249298.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-424-9298.
-
MPN or Model
NE114020
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
1.8 lb -
Body Style
Single pole type -
Body Length
6.218 inches -
Body Width
4.125 inches -
Body Height
3.406 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
5.250 inches -
Unthreaded Mounting Hole Diameter
0.190 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
5.250 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.187 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 unthreaded hole -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location and 20.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 125.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac single location and 10000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal-magnetic single location -
Trip Release Characteristic
Instantaneous single location and time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
11.000 at 200 pct single location and 30.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
General purpose -
Trip Release Ambient Tempurature Rating
40.0 degrees celsius single location -
Frequency In Hertz
60.0 single location -
Terminal Type And Quantity
2 compression
More from these suppliers
- 5930-01-160-7042 MPN MDS00012Rotary Switch
- 6110-01-191-7736 MPN DA83-01-069-011Motor Starter
- 6110-01-192-9883 MPN DA83-01-069C-052Motor Starter
- 6110-01-253-1115 MPN SL-8306.219.C010Motor Starter
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-424-9298 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
NE114020 | Challenger Electrical Equipment Corp |
NE113020 | Challenger Electrical Equipment Corp |
Stock Check
![](/public/images/partscage_shelf3.png)