NSN 5925-00-430-6343
Overload Switch
0.164 inches mounting slot width, plastic case material, 2 poles, arc quenching method: magnetic blowout.
Manufacturer part number CF2G3U50-240-1 for national stock number 5925004306343.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-430-6343.
-
MPN or Model
CF2G3U50-240-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Mounting Slot Width
0.164 inches -
Body Length
5.844 inches -
Body Width
2.072 inches -
Body Height
2.609 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
4.502 inches -
Center To Center Distance Between Terminals Parallel To Width
1.032 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.032 inches -
Boss Height
0.219 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 terminal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip all locations -
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 at 200 pct all locations and 125.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
4 compression
More from these suppliers
- 5925-00-081-3823 MPN PSM333-0.75-240-400Circuit Breaker
- 5925-00-081-8720 MPN HB3Z1-59Circuit Breaker
- 5925-00-163-6547 MPN JA1-B3-A-20-2Circuit Breaker
- 5925-00-185-4020 MPN XAM33M6-20Circuit Breaker
- 5925-00-236-5274 MPN 64-174-2MG4Circuit Breaker
- 5925-00-660-6680 MPN PXAM333MG6Circuit Breaker
- 5925-00-944-3847 MPN AM12HK1-32VDC5Circuit Breaker
- 5925-01-020-7323 MPN XAM33MG350125AC5Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-430-6343 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
CF2G3U50-240-1 | Eaton Corp |
209-2-1-63F4-2-50 | Sensata Technologies Maryland, Inc |
CF2G3U50-240-9 | Eaton Corp |