NSN 5925-00-432-0121
Overload Switch
Plastic case material, 3 poles, general purpose warehouse storage type, maximum continuous load current rating per pole: 50.0 amperes ac all locations.
Manufacturer part number TED134C5050WL for national stock number 5925004320121.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-432-0121.
-
MPN or Model
TED134C5050WL
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
3.8 lb -
Body Length
6.310 inches -
Body Width
4.125 inches -
Body Height
3.380 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
5.250 inches -
Center To Center Distance Between Terminals Parallel To Width
1.375 inches -
Unthreaded Mounting Hole Diameter
0.188 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.880 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.380 inches -
Boss Height
0.125 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
4 unthreaded hole -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Trip Delay Time In Seconds Per Rated Continuous Current
0.900 at 200 pct all locations -
Inclosure Protection Type For Which Designed
General purpose -
Trip Release Ambient Tempurature Rating
50.0 degrees celsius all locations -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
6 compression
More from these suppliers
- 5940-01-447-9837 MPN EB27A04STerminal Board
- 5925-00-833-7952 MPN TF126015Circuit Breaker
- 5925-01-186-4601 MPN TEC36030WL/TEDAS2AB1RS/TLD3Circuit Breaker
- 5925-01-458-2647 MPN TKMASTA12RSCircuit Breaker Tripper
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-432-0121 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
TED134C5050WL | General Electric Co |
TED134C5050 AND (6) TCAL12 | General Electric Co |