NSN 5925-00-450-5340
Overload Switch
Plastic case material, 1 poles, general purpose warehouse storage type, maximum continuous load current rating per pole: 100.0 milliamperes ac single location and 100.0 milliamperes dc single location.
Manufacturer part number 4-833-3 for national stock number 5925004505340.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-450-5340.
-
MPN or Model
4-833-3
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Case Material
Plastic -
Unthreaded Mounting Hole Diameter
0.138 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
2 unthreaded hole -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
100.0 milliamperes ac single location and 100.0 milliamperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location and 24.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push button -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 control -
Internal Trip Release Configuration
Series trip single location -
Switch Location And Position Designation
External at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 at 200 pct single location and 40.000 at 200 pct single location -
Frequency In Hertz
60.0 single location -
Terminal Type And Quantity
2 tab, solder lug
More from these suppliers
- 5925-01-406-3487 MPN 46-500-P10-1.5ACircuit Breaker
- 5945-00-007-7592 MPN 2805554P3Thermal Relay
- 5945-00-779-6167 MPN PT7403Thermal Relay
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-450-5340 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
4-833-3 | Spx Corporation |
46-200-0-1AMP | Oakland Industries Ltd |