NSN 5925-00-455-7733
Overload Switch
Multipole-multiple actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number APL1111-663-1 for national stock number 5925004557733.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-455-7733.
-
MPN or Model
APL1111-663-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
1.1 lb -
Body Style
Multipole-multiple actuator type -
Body Length
Between 2.480 inches and 2.500 inches -
Body Width
3.015 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.940 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.735 inches and 0.765 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.050 inches and 2.070 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.735 inches and 0.765 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.150 inches -
Mounting Surface To Terminal End Distance
2.625 inches -
Pole Quantity
4 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
8 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
100.0 milliamperes dc second location -
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc second location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay first location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
4 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, three, and four linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole four -
Trip Delay Time In Seconds Per Rated Continuous Current
0.700 at 200 pct first location and 10.000 at 200 pct first location -
Inclosure Protection Type For Which Designed
Corrosion resistant and moisture resistant and shockproof and vibrationproof and fungus resistant -
Switch Terminal Type
Pin -
Switch Current Rating And Type In Amps
10.0 ac and 10.0 dc -
Unpackaged Unit Weight
14.800 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
8 threaded stud
More from these suppliers
- 5945-00-435-2486 MPN 36-0505Electronic Chopper
- 5945-00-791-4544 MPN 600Electronic Chopper
- 5925-01-025-7007 MPN AP-112-1-61-402Circuit Breaker
- 5925-01-052-5123 MPN APL111-1RE-42-102MACircuit Breaker
- 5925-01-141-6684 MPN AP-12-1R-62F-751Circuit Breaker
- 5925-01-156-7725 MPN AP-12-1-64F-802Circuit Breaker
- 5925-01-160-7607 MPN AP-12-1-65F-502Circuit Breaker
- 5925-01-232-6046 MPN IPG-6-1-42-103-00Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-455-7733 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
APL1111-663-1 | Sensata Technologies Maryland, Inc |
APL1111-663-1 | Sensata Technologies Maryland, Inc |